In addition to the well-known top dogs such as Cisco, HP and Juniper, also Huawei is steadly spreading in the field of network devices. I have taken this fact as an impulse to connect a Huawei 2751 S2751- 28TP-PWR-EI-AC to a NetEye appliance and to test which information can be retrieved.
The device I tested is a switch with 24 100Mbit ports and 4 Gigabit ports.
To prepare it, a basic configuration has to be made and we have to make sure, that also the SNMP agent and a SSH configuration are active.
The first tool of the NetEye-Suite, which relates information from the switch, is the Discovery Module based on NeDi.
To query the data from the switch, some settings in the nedi.conf file have to be adjusted.
1. The SNMP Community:
2. Activate CLI access
3. SSH access data
Now, if you run a discovery on the switch, a significant flood of data is transmitted and displayed in the NetEye Discovery.
Since we have also activated an SSH access and the CLI access, NeDi can backup the configuration of the switch and store it on the NetEye server, to be subsequently recalled or compared with the following configurations.
After the Huawei switch has been detected and recorded, we can add the device to the monitoring and monitor it with the appropriate checks.
The easiest way to import the device is the usage of the “NeDi Import” wizard, which helps to import devices from NeDi into the NetEye monitoring and optionally assigns a host profile to it.
Once, the switch has been added, you can query it with the appropriate checks.
As SNMP was already activated for NeDi, the protocol can now also be used for monitoring.
The checks listed above have been tested and provide results which are illustrated as graphs by PNP4Nagios.
The check “SNMP_Interface_Table” shows an overview of important information and is able to indicate divergence from default values, if configured correctly.
This was an overview of the requests that I have addressed to the switch. I hope this post was clear and helpful for you.
Hi, I’m Patrick.
Since I was a little boy i love to diassemble and reassemble things...
So I did with my first 386SX back in the 80s... and I still do with my i7 up till now.
I worked in the Service Desk then grew up to a DBA and work now as Integration Consultant at Würth Phoenix.
Author
Patrick Agreiter
Hi, I’m Patrick.
Since I was a little boy i love to diassemble and reassemble things...
So I did with my first 386SX back in the 80s... and I still do with my i7 up till now.
I worked in the Service Desk then grew up to a DBA and work now as Integration Consultant at Würth Phoenix.
Error during generation of SLA reports We have fixed a bug that was causing an error during the generation of SLA reports. List of updated packages To solve the issue mentioned above, the following packages have been updated for NetEye Read More
Fix NagVis navigation using IcingaDB Web URLs When clicking on a host or service from a NagVis map, you were redirected to the legacy Monitoring module. The links have been updated to correctly point to the IcingaDB Web module. List Read More
Fixing Misplaced Plugin Output in Icinga Web Interface When plugin output contained HTML content (like links), it was incorrectly displayed near the service name instead of in the Plugin Output section. The plugin output section now correctly renders all content. Read More
Icinga Director Now Responsive During Configuration Deployments Previously, users were unable to interact with Icinga Director while configuration deployments were running. Any attempt to access the interface or API would be blocked until the deployment completed, causing unnecessary delays in Read More
Bug Fix We updated the version of GLPI in order to fix some relevant vulnerabilities. List of updated packages The following packages have been updated for NetEye 4.45: glpi, glpi-autosetup, glpi-configurator, glpi-neteye-config to version 10.0.22_neteye1.17.5-1.